Detail Blastmate III (blasting Monitor)
General Specifications
* Channels : Microphone and Triaxial Geophone or 4 independent user configurable channels ( two microphones and two Triaxial Geophones or 8 independent channels with optional 8 channel upgrade )
* Vibration Monitoring ( with Standard Triaxial Geophone )
Range : Up to 254 mm/s ( 10 in /s )
Resolution : 0.127 mm/s (0.005 in/s) or 0.0159 mm/s (0.000625 in/s) with
built in preamp
Accuracy : +/- 5% or 0.5 mm/s (0.02 in/s), whichever is larger, between
4 and 125 Hz /DIN 45669-1 standard
Transducer Density : 2.13 g/cc ( 133 lbs/ft3)
Frequency Range : 2 to 250 Hz, within zero to -3 dB of an ideal flat response /1 to 315 Hz
* Air Overpressure Monitoring
Weighting Scales : Linear or A Weight
Linear Range : 88 to 148 dB ( 500 Pa ( 0.072 PSI ) Peak )
Linear Resolution : 0.25 Pa ( 0.0000363 PSI )
Linear Accuracy : +/- 10% or +/- 1 dB, whichever is larger, between 4 and 125 Hz
Linear Frequency Response : 2 to 250 Hz Between -3 dB roll off points
A -Weight Range : 50 to 110 dBA
A-Weight Resolution : 0.1 dBA
* Maximum Cable Length ( ISEE / DIN ) : 75 m ( 250 ft ) / 1,000 m ( 3,280 ft )
Waveform Recording
* Record Modes : Manual, Single shot, Continuous
* Seismic Trigger : 0.125 to 254 mm/s ( 0.005 to 10 in/s)
* Acoustic Triggers
Linear : 100 to 148 dB
A Weight : 55 to 110 dBA
* Sample Rate : 1.024 to 16,000 S/s per Channel ( independent of record time )
up to 65,000 S/s
in single channel mode with advanced software (maximum 8,000 S/s
per channel for 8 channels )
* Record Stop Modee : Fixed record time, Instantel Auto Record , record stop mode
* Record Time : 1 to 100 seconds ( programmable in one second steps ) or 500
seconds plus 0.25 seconds pre trigger
* Auto Record Time : Auto window programmable from 1 to 9 seconds, plus a 0.25 second
pre trigger. Events is recorded until activity remains below trigger level
for duration of auto window, or until available memory is filled
* Cycle Time : Recording uninterrupted by event processing - No dead time
* Storage Capacity
Full Wavefrom events : 300 one second events at 1,024 S/s sample rate ( 1,500 event capacity
with optional memory upgrade )
Event Summaries : 1,750 ( 8,750 event capacity with memory upgrade )
Histogram Recording
* Record Modes : Histogram and Instantel Histogram Combo ( monitor captures
triggered waveforns while recording in Histogram mode )
* Recording Intervals : 2,5 or 15 seconds; 1, 5 or 15 minutes
* Storage Capacity : 46,656 intervals 3 days at 5 second intervals or 102 days at
15 minutes intervals
( with memory up grade 15 days at 5 second intervals or 540 days at
15 minutes intervals )
Physical Specifications
* Dimensions : 269 x 355 x 165 mm ( 10.6 x 14.0 x 6.5 in )
* Weight : 6.4 Kg ( 14 Lbs )
* Battery : Rechargeable 6 V sealed gel cell capacity for 30 days of continuous monitoring
* User Interface : 63 domed tactile keys including full keyboard and dedicated keys for common fucntions